Retrofit of AECL CAN6 Seals into Pickering Shutdown Cooling Pumps

Main Article Content

David Rhodes
Ray Metcalfe
Gordon Brown
Philip Kiameh
Paul Burchett

Abstract

The existing mechanical seals in the shutdown cooling (SOC) pumps at the eight-unit Pickering Nuclear Generating Station have caused at least seven forced outages in the last fifteen years. The SOC pumps were originally intended to run only during shutdowns, mostly at low pressure, except for short periods during routine testing of SOC isolation valves while the plant is operating at full pressure to verify that the emergency core injection system is available. Unfortunately, in practice, some SOC pumps must be run much more frequently than this to prevent overheating or freezing of components in the system while the plant is at power. This more severe service has decreased seal lifetime from about 8000 running hours to about 3000 running hours. Rather than tackling the difficult task of eliminating on-power running of the pumps, Pickering decided to install a more robust seal design that could withstand this. Through the process of competitive tender, AECL's CAN6 seal was chosen. This seal has a successful history in similarly demanding conditions in boiling water reactors in the USA. To supplement this and demonstrate there would be no "surprises," a 2000-hour test program was conducted. Testing consisted of simulating all the expected conditions, plus some special tests under abnormal conditions. This has given assurance that the seal will operate reliably in the Pickering shutdown cooling pumps.